Product · Integrated rail system simulation software

SimuX

SimuX is software developed at Istanbul Technical University that simulates a rail transport system with all of its components for traction power, signalling, operation and energy efficiency studies. Development continues in line with the needs of the industry.

Product summarySX
What
Integrated software that simulates a rail transport system with all of its components.
For whom
Authorities, operators, designers and contractors testing lines under construction or in service.
How
Train performance and electrical load flow are solved together at each time step, down to 100 ms or less.
Interface
Hi-SimuX: HI-SIM’s software interface to the SimuX core
Validation
EN 50641:2020 (AC) and CLC/TS 50641-2:2024 (DC) attestations of conformity, TÜV NORD Turkey; EN 50388 mean useful voltage
Origin
Istanbul Technical University; first version 2003
Train and power system solved togetherAt every time step the train dynamics set the power demand and the load flow sets the pantograph voltage; a lower voltage limits the tractive effort.MODEL ATrain dynamicstractive effort · accelerationspeed · positionmotoring / regen brakingMODEL BLoad flowsubstations · feederscatenary / third railreturn rail · VLDpower demandpantograph voltageΔt≤100 mst₀SOLVED TOGETHER AT EVERY TIME STEPtₙTrain and power system solved togetherAt every time step the train dynamics set the power demand and the load flow sets the pantograph voltage; a lower voltage limits the tractive effort.MODEL ATrain dynamicstractive effort · accelerationspeed · positionmotoring / regen brakingMODEL BLoad flowsubstations · feederscatenary / third railreturn rail · VLDpowerdemandpantographvoltageΔt≤100 ms
Δt ≤ 100 msIteration time, depending on the project
EN 50388Mean useful voltage for mainline railways
2003First version of SimuX; Istanbul Technical University
VLD · ESSVoltage limiting devices and on-board energy storage models

What SimuX determines

  • Train performance under operating conditions
  • Dimensioning of the traction power system
  • Adequacy of the traction system, feeder cables and catenary / third rail
  • Maximum, minimum and average voltage at a train’s pantograph
  • Rail potential and stray current
  • Energy consumption and losses
  • Energy saving strategies, tested before they are applied
  • The effect of regenerative braking and the line’s receptivity and recuperation ratios
  • The effect of different feeding schemes
  • Short-circuit currents

EN 50641 certified traction power simulation

The SimuX simulation core and its software interface Hi-SimuX were assessed by TÜV NORD Turkey against EN 50641, the standard for validating simulation tools used to design electric traction power supply systems, and hold two attestations of conformity: EN 50641:2020 for AC systems and CLC/TS 50641-2:2024 for DC urban systems. The certificates name the product “Hi-SimuX Rail System Simulation Suite, version 2024.01”; since the calculations are made by the SimuX core, the certificates apply to both SimuX and Hi-SimuX.

Certificate No.Standard and scopeAssessment reportValid
CR-AOC-TUVNORD-24/0089-R01EN 50641:2020; AC 15 kV 16.7 Hz case and AC 25 kV 50 Hz lumped elements caseRP-AOC-TUVNORD-24/0088-R0018.09.2024 – 18.09.2029
CR-AOC-TUVNORD-24/0091-R01CLC/TS 50641-2:2024; specific DC urban case: 750 V DC, implicit validation for 600, 750, 1500 and 3000 V DCRP-AOC-TUVNORD-24/0090-R0008.10.2024 – 08.10.2029

EN 50388 The mean useful voltage (Umean useful) required by EN 50388 for mainline railways is calculated with SimuX and Hi-SimuX, and values such as pantograph and rail voltage are compared with the limits in the standards.

Issued by TÜV NORD Turkey Teknik Kontrol ve Belgelendirme A.Ş., Istanbul, 20.12.2024. The attestations are issued on a voluntary basis and cover the product version and technical documentation submitted for inspection.

TÜV NORD attestation of conformity CR-AOC-TUVNORD-24/0089-R01, SimuX / Hi-SimuX, EN 50641:2020
EN 50641:2020, AC 15 kV 16.7 Hz case and AC 25 kV 50 Hz lumped elements case.
TÜV NORD attestation of conformity CR-AOC-TUVNORD-24/0091-R01, SimuX / Hi-SimuX, CLC/TS 50641-2:2024
CLC/TS 50641-2:2024, specific DC urban case: 750 V DC, with implicit validation for 600, 750, 1500 and 3000 V DC.

Model inputs

The software takes many variables into its model to bring results close to real operating conditions. The main inputs are:

  • Names, lengths and numbers of lines; passenger stations with minimum and maximum dwell times (random or fixed)
  • Curves, gradients, speed limits and maximum operating speed
  • Data on the depots connected to the lines
  • Operation rules: cars per train, headways, departure and arrival points, skip-stop stations
  • Number, location and naming of substations, their equipment data, isolating sections, catenary / third-rail data and the rail potential control device
  • Vehicle data: maximum speed, empty/full weight, maximum acceleration, braking and jerk, tractive effort–speed and braking effort–speed diagrams

Dynamic simulation: train and power system together

Unlike most competing products, SimuX’s dynamic algorithms model the interaction between trains and the power system at every time step, as conditions change along the alignment. Voltage at the train affects its performance: when the voltage falls, the acceleration, speed and position of the train change. The power drawn by the train falls and the power system partly recovers from the sag. SimuX models this non-linear control function for both motoring and regenerative braking.

The mean useful voltage required by EN 50388 for mainline railways can be calculated with SimuX. Thanks to its modelling of current and power limitation at low voltage and of voltage limiting devices (VLD) on the return circuit, SimuX finds the achievable headway even in worst cases such as two neighbouring substations out of service.

SimuX analyses the impact of train bunching and whether the power supply can support several “stacked” trains restarting at once. Because many train types and compositions can share one model, it supports integrated operating plans; and because passenger load can differ between stations, systems are dimensioned more realistically.

With on-board energy storage systems (ESS) and catenary-free zones in the simulation, the ESS can be dimensioned and the charging times in the designated areas optimized. Depending on the project, the iteration time can be 100 milliseconds or less, so that critical values such as rail voltage are fully checked against the standards.

In historic and touristic areas a single contact wire often makes buried reinforcing feeder cables necessary in tram projects. SimuX models these cables and their connection points to the contact wire separately, to optimize cable size and connection frequency. Cables parallel to the running rail can also be modelled to reduce rail voltage. Options like these prevent over-sizing and keep simulation-based investment decisions accurate.

Validation in projects

The software has been used successfully in many projects, both for lines under construction and for testing lines in service against new conditions, and its results have been confirmed to be very close to real values.

The first version of SimuX was developed in 2003; it builds on a 25 kV AC simulation program written as an MSc thesis in 1994. See our history.

FAQ

Is SimuX certified to EN 50641?

Yes. The SimuX core and its software interface Hi-SimuX (named on the certificates as Hi-SimuX Rail System Simulation Suite, version 2024.01) hold two attestations of conformity from TÜV NORD Turkey: EN 50641:2020 for the AC 15 kV 16.7 Hz case and the AC 25 kV 50 Hz lumped elements case (CR-AOC-TUVNORD-24/0089-R01, valid until 18.09.2029), and CLC/TS 50641-2:2024 for the specific DC urban case, 750 V DC with implicit validation for 600, 750, 1500 and 3000 V DC (CR-AOC-TUVNORD-24/0091-R01, valid until 08.10.2029).

What is EN 50641?

EN 50641 is the European standard for railway fixed installations that sets requirements for validating simulation tools used to design electric traction power supply systems. The core functions that compute train movement and the load flow of the supply system are checked against the reference test cases in the standard. CLC/TS 50641-2:2024 applies this approach to DC urban systems such as tramways and metros.

Which supply systems do the certificates cover?

On the AC side 15 kV 16.7 Hz and 25 kV 50 Hz (lumped elements case); on the DC side the 750 V DC urban case, with implicit validation for 600, 750, 1500 and 3000 V DC.

Can EN 50388 checks be made?

Yes. The mean useful voltage defined in EN 50388 for mainline railways is calculated with SimuX and Hi-SimuX, and values such as rail voltage are compared with limits from international standards.

Can on-board energy storage be modelled?

Yes. On-board energy storage and catenary-free zones are included in the simulation, so the storage can be dimensioned and the charging dwell times optimized.

Where was SimuX developed?

SimuX was developed at Istanbul Technical University; its first version dates from 2003, and development continues in line with industry needs.

Do you need simulations for your project?

Write to us about your traction power, headway, train movement or energy efficiency studies, and we will scope your project needs together.

[email protected]